您好,歡迎來到維庫儀器儀表網(wǎng) 免費(fèi)注冊(cè) 登錄 忘記密碼
| 品牌 | ABB | 型號(hào) | TB4042,TB4043 |
| 測量范圍 | 見技術(shù)要點(diǎn) | 測量精度 | 見技術(shù)要點(diǎn) |
| 分辨率 | 見技術(shù)要點(diǎn) | 電源 | 見技術(shù)要點(diǎn) |
| 尺寸 | 見技術(shù)要點(diǎn)(mm) | 用途 | 見技術(shù)要點(diǎn) |
Conductivity Cell TB4042
The Conductivity Cell TB4042 expands the advancements in process conductivity measurement initiated by ABB with four-electrode conductivity measurement. Unlike four-electrode sensors, toroidal sensors have no electrodes.The TB4042 Toroidal Conductivity Sensor provides a means for measuring solution conductivity in chemically aggressive solutions that corrode, foul, or otherwise destroy electrode type sensors. The sensor itself is comprised of two wound toroids encapsulated in a chemically resistant nonconductor made of polyetherether ketone (PEEK). Measurement is made inductively via magnetic coupling between the solution and the toroids. Because measurement is made inductively, without electrodes that can be affected by erroneous resistances from foulants or coatings, these sensors are virtually impervious to all but thick layers of foulants.
Conductivity Cell TB4043
The Conductivity Cell TB4043 expand the advancements in process conductivity measurement initiated by ABB with four-electrode conductivity measurement. Unlike four-electrode sensors, toroidal sensors have no electrodes.Sanitary toroidal conductivity measurements is applicable to a wide variety of process needs including: dairy, food and beverage, pharmaceutical, clean-in-place, brine, cheese souring, lye peeling and countless other applications.